Refrigerated display cabinets are widely used in supermarkets, convenience stores, hotel catering, fruit and cake chains. Refrigerated display cabinet in the use of the process, sometimes there will be water leakage phenomenon. Water leakage usually does not occur, so, what causes the cold storage display cabinet water leakage? And how?
The cause of refrigerated display cabinet water leakage is more, more common, such as: due to the higher temperature, refrigerated display cabinet refrigeration system working intensity big, condensed water is more than usual, refrigerated display cabinet internal water pans is full, there is no way to continue to hold water, lead to overflow to the ground, this kind of situation usually appear in the summer. In addition, if there is too much water in the evaporator at the bottom of the refrigerated display cabinet, it will flow to the ground and cause water accumulation. Or refrigerated display cabinet water and evaporator did not put straight, more likely because of poor quality of equipment, use time too long lead to aging leakage.
Of course, the above is the main reason, there are some operational problems may lead to. For example, the high water content of food in the refrigerated display cabinet and blocked drain pipes can also lead to water accumulation in the refrigerated display cabinet. Because of too much moisture, the water after defrosting cannot be imported into the water tray and evaporator, which leads to flow into the inside of the refrigerated display cabinet, which is quite serious. So how to deal with the stagnant water in the refrigerated display cabinet?
Before dealing with a fault, you should fully understand the cause of the fault. In fact, find the cause of the remedy can be. For example, the water plate and evaporator caused by the water only need to put the plate, evaporator inside the water, can prevent overflow. Check again to check whether the position of the water plate and evaporator is aligned, as long as the evaporator has no fault, the internal water will flow into it without Yin, no more water.
For foods that need to be stored in refrigerated display cases, try to remove as much moisture as possible, or wrap them in plastic wrap to reduce moisture in the equipment. If the water tray or other equipment problems should be timely maintenance or replacement. Regular manufacturers have after-sales service, large refrigerator display cabinets are generally door-to-door service, such as youkai refrigeration, customers have problems, if telephone guidance can not be quickly solved, will contact door-to-door processing, but small manufacturers or in some treasure above the purchase of refrigeration display cabinets, it needs to think of their own way to deal with.